3.9 Distribution Frame Examination
3.9.1 Examination of optical cable distribution frame shall meet the following requirements:
1 For the distribution frame,the coating on its surface shall be smooth,evenly-colored,without any sagging or exposure;its metal ware shall be free from any burrs or rusts.The labels on the frame shall be complete,clear,accurate and durable.
2 The frame shall have all the function modules completely installed.
3 Insulation resistance between earthing device and frame rack,as well as high voltage tolerance,shall comply with the requirements of current professional standard Optical Fiber Distribution Frame YD/T 778 or the design requirements.
3.9.2 Connector examination shall meet the following requirements:
1 Connector shall be free from any stain,burr,crack,losing-off,deformation or shift and shall be clearly marked.
2 Connection and disconnection between connector plug and adapter shall be smooth,easy,firm and flexible to ensure normal functioning.
3 Optical fiber cables of connector shall be smooth and glossy,without any impurities or damage,and with legible printing and required colors.
4 Insertion loss and return loss shall meet the design requirements.
3.9.3 Cable distribution frame examination shall meet the following requirements:
1 For the cable distribution frame,its coating on the surface shall be smooth,evenly-colored,without any sagging or exposure;the labels on the frame shall be complete,clear,accurate and durable.
2 Metal ware shall have smooth coating(plating)without any obvious difference,scars,rusts or flakes.
3 Plastic ware shall be evenly-colored,without any obvious difference,crack or scar.
4 Fastener shall be provided in full and firmly installed,with its frame and connector bars horizontally and vertically aligned.
5 The labels on the frame shall be complete,clear,accurate and durable.
6 Insulation resistance between protective earthings,between any independent connectort-erminals,between any connector terminal and metal fastener,as well as overvoltage or overcurrent protectors shall comply with the requirements of current professional standard Main Distribution Frame YD/T 694.