3.2 Selection of Lining Structure
3.2.1 Heat-insulating and abrasion-resistant linings shall be classified into the following types based on the lining structures and performance of lining concrete:
1 Double layer heat-insulating and abrasion-resistant lining with hexmesh[Figure 3.2.1(a)];
2 Single layer abrasion-resistant or highly abrasion-resistant lining with hexmesh[Figure 3.2.1(b)];
3 Double layer heat-insulating and abrasion-resistant lining without hexmesh[Figure 3.2.1(c)];
4 Single layer heat-insulating and abrasion-resistant lining without hexmesh[Figure 3.2.1(d)];
5 Single layer abrasion-resistant or highly abrasion-resistant lining without hexmesh[Figure 3.2.1(e)].
3.2.2 Single layer heat-insulating and abrasion-resistant lining without hexmesh should be used as the lining structure for the following reactor generator system equipment:
1 Regenerator;
2 Coke combustor and withdrawal well;
3 Catalyst cooler;
4 Y-shaped position of reactor riser;
5 Third-stage cyclone/separator.
3.2.3 Double layer heat-insulating and abrasion-resistant lining with hexmesh should be used as the lining structure for the following reactor generator system equipment:
1 Orifice chamber;
2 Cold wall dipleg;
3 Slide valve;
4 Cold wall cyclone/separator.
Figure 3.2.1 Heat-insulating and Abrasion-resistant Lining Structures
1—Heat-insulating concrete;2—Cylindrical anchor;3—End plate;4—Hexmesh;5—Abrasion-resistant/highly Abrasion-resistant concrete;6—Ω-anchor;7—Metal Reinforcing fiber;8—Heat-insulating and abrasion-resistant concrete;9—Stud bolt;10—Y-anchor;11—V-anchor;12—S-anchor;13—Ring anchor
3.2.4 Double layer heat-insulating and abrasion-resistant lining with hexmesh should be used and single layer heat-insulating and abrasion-resistant lining without hexmesh may be also used as the lining structure for the following reactor generator system equipment:
1 Reactor(disengager);
2 Reactor riser;
3 Standpipe;
4 Flue duct.
3.2.5 Single layer highly abrasion-resistant lining with hexmesh should be used as the lining structure for the following reactor-regenerator system equipment,operating conditions and similar positions:
1 Hot wall cyclone;
2 Hot wall dilute phase pipe;
3 Hot wall dipleg.
3.2.6 Single layer highly abrasion-resistant lining without hexmesh shall be used as lining structure for the following locations subject to erosion due to high gas speed:
1 Air distribution pipes or distribution plates;
2 Thermowells of reactor riser.
3.2.7 For the locations subject to severe erosion such as outlet of slide valve,double layer heat-insulating and abrasion-resistant lining with hexmesh shall be used,highly abrasion-resistant concrete shall be used for the abrasion-resistant lining,and the thickness of abrasion-resistant lining shall be increased.